Fixed, Resolved, or Included in This Release

Topics:

This section lists fixed, resolved, or included functionality for iWay E-Business Adapters in iWay version 8.0.4.

X12

Batching for outbound documents is now available. For more information, see the iWay Integration Solution for EDI X12 User's Guide.

HIPAA

Batching for outbound documents is now available. For more information, see the iWay Integration Solution for HIPAA User's Guide.

EDIFACT

Batching for outbound documents is now available. For more information, see the iWay Integration Solution for EDIFACT User's Guide.

EDIHL7

  • The Ebix attach screen has been corrected for HL7.
  • Generating metadata created indistinguishable tags for many documents. Many of these were fixed by adding artificial loops (HL7 version 2.3, 2.3.1, 2.4, 2.5, 2.5.1, 2.6, 2.7, 2.7.1, 2.8 and 2.8.1). Note that there are remaining fields, which create what appear to be validation errors. Many of these are fields that require the user to insert data into the tags. If you encounter one of these and need assistance in making the required modifications, contact Information Builders Customer Support. The corrected Ebix files are available for download from https://techsupport.informationbuilders.com.
  • Corrected names of several documents to remove stray hex characters from the document names.
  • HL7 version 2.7.1 and other versions had missing or inconsistent maximum field lengths. This has been resolved.

HL7 (Older Version)

Starting iWay Service Manager may display a message indicating that the _HL7 Ack Agent was being linked. This agent was removed in iWay 8.x.

Note: As of iWay version 8.0, the iWay E-Business Adapter for HL7 is deprecated.

SWIFT

  • The SWIFT 2020 release will be available on or after June 30, 2020.
  • SWIFT 2020 will only be available in the iWay 8.0.4 release track.

Documentation

Workspace Samples

  • All workspace samples have been updated in this release.
  • Chapter 4 in each user guide documents how to download the workspace samples, import the samples to iWay Integration Tools (iIT), and deploy the samples.

iWay Integration Tools

  • An Ebix file name cannot have two or more period (dot) characters in the name. As a workaround, rename the Ebix file.
  • Renaming a project now correctly renames all of the associated artifacts. After renaming a project or parts of a project, inspect the bundle in the workspace and ensure that all of the older items have been deleted. If not, you may delete them.