You must perform the following steps to connect to your
Siebel system (version 6.2 and lower) using COM connectivity for
an iBSP configuration.
- Install the
Siebel thick client on the same machine where the adapters are installed.
- Install the
database client (Microsoft SQL Server or Oracle) on the same machine.
- The Siebel
.DLL files (iwsiebel.local.dll and iwsiebel.core.dll) must be added
to the classpath. These files are located in the following directory:
<iway_home>\lib
- Locate the
uagent.cfg file in the following Siebel thick client directory:
drive:\sea\client\bin
- Edit the uagent.cfg
file and change the data source parameter value from "local" to "server".
In
addition, ensure that the following parameters are configured as
shown:
EnableOLEAutomation = TRUE
OLEAutomationDLL = sscfole.dll
- Edit the data
source for SEA MSQl with appropriate parameters.
You can edit
a data source in Windows by accessing the Control Panel, Administrative Tools,
and Data Sources (ODBC).
- Use the following
target type when creating the adapter target connection:
Siebel 6.2 - (Local COM Access Implementation)
- Provide the
full path to the uagent.cfg file when creating an adapter target
connection, for example:
drive:\sea\client\bin\uagent.cfg